Publication | Closed Access
Gait variability measurements in lumbar spinal stenosis patients: part B. Preoperative versus postoperative gait variability
27
Citations
17
References
2009
Year
Gait AnalysisLumbar SpineLss PatientsMedicinePreoperative Gait VariabilityGait VariabilityMotor ControlRehabilitationApplied PhysiologyPathological GaitHuman MovementRehabilitation EngineeringSpine SurgerySpinal DisorderOrthopaedic SurgeryGait Variability MeasurementsHealth Sciences
The objective of this study was to assess the gait variability of lumbar spinal stenosis (LSS) patients and to evaluate its postoperative progression. The hypothesis was that LSS patients' preoperative gait variability in the frequency domain was higher than the corresponding postoperative. A tri-axial accelerometer sensor was used for the gait measurement and a spectral differential entropy algorithm was used to measure the gait variability. Twelve subjects with LSS were measured before and after surgery. Preoperative measurements were performed 2 days before surgery. Postoperative measurements were performed 6 and 12 months after surgery. Preoperative gait variability was higher than the corresponding postoperative. Also, in most cases, gait variability appeared to decrease throughout the year.