Journal of Nuclear Science and Technology · 2008 · 25 citations · 17 references
EngineeringNuclear EngineeringFluid DynamicsHeat TransferUltrasoundDoppler UltrasoundDoppler Velocity MeasurementFlow MeasurementFlow MetrologyPipe FlowUltrasonicsDoppler MeasurementsPipe Flow MeasurementPipe RoughnessReynolds NumberReynolds Number EffectsSurface Roughness ParametersVelocity Profile AnalysisVelocity Profiles
The velocity profile of the flow in a pipe and its influence on the profile factor used with conventional flow meters were investigated with ultrasonic pulse Doppler measurements. From the measured velocity profiles, the influences of surface roughness and Reynolds number were characterized qualitatively and quantitatively. As pipe surface roughness changes during plant operation, the velocity profile changes, producing a change in the profile factor. Variation in the Reynolds number also influences the change in the profile factor. Experiments were conducted at high temperature and pressure to evaluate the ultrasonic pulse Doppler method for measuring the flow of nuclear plant cooling water. Helium gas bubbles provided sufficiently persistent ultrasonic reflectors when injected into high-pressure water, permitting the velocity profile of the flow to be obtained under high-temperature and high-pressure conditions using this method.
17
Mean-flow scaling of turbulent pipe flow
Mark Zagarola, Alexander J. Smits · Journal of Fluid Mechanics · 1998 · 792 citations
Development of an ultrasound velocity profile monitor
Y. Takeda · Nuclear Engineering and Design · 1991 · 293 citations
Medicine, Radiology, Instrumentation +11
Flow Measurement and Instrumentation
Flow Measurement and Instrumentation · 2021 · 149 citations