Vox Sanguinis · 1993 · 14 citations · 10 references
MedicineHematologyClinical PharmacologyHematopathologyHemostasisCoagulation AbnormalitiesCoagulation Factor DeficienciesCoagulation Factor ConcentratesFactor ViiaInhibitor Specificity
The levels of anti-human and anti-porcine factor VIII inhibitors, measured in 63 severe haemophilia A patients, lay in the ranges of < 0.2-2,600 and < 0.2-1,300 Bethesda units per ml (BU/ml), respectively, with a median cross-reactivity of 33%. In 4 patients, human and porcine inhibitor levels were determined using both plasma, either human or porcine, and factor VIII concentrate, either very high purity human or porcine (Hyate:C). A good correlation between titres was found, whatever the source of factor VIII (plasma or concentrate). The cross-reactivity varies from 0 to over 100%, indicating that the evaluation of both human and porcine inhibitors should be mandatory before any treatment with Hyate:C. Results show that of the 46 patients with human inhibitor of more than 5 BU/ml, 21 (46%) with a low porcine inhibitor (< 5 BU/ml) could benefit from Hyate:C.
10
A More Uniform Measurement of Factor VIII Inhibitors
Carol K. Kasper, Louis M. Aledort, David L. Aronson et al. · Thrombosis and Haemostasis · 1975 · 587 citations
Progress in Clinical and Biological Research
A L Crombie · British Journal of Ophthalmology · 1989 · 553 citations · Full text
Acquired inhibitors of blood coagulation.
DI Feinstein, Samuel I. Rapaport · PubMed · 1972 · 519 citations
Medicine, Hematology, Hemostasis +9
A More Uniform Measurement of Factor VIII Inhibitors
Carol K. Kasper, Louis M. Aledort, Richard B Counts et al. · Thrombosis and Haemostasis · 1975 · 320 citations