Journal of Applied Physics · 1997 · 56 citations · 9 references
EngineeringElectrical EngineeringPhysicsElectromagnetismFinite Element AnalysisFinite Element MethodsElectromagnetic InductionLosses In Electric MachinesMagnetic Circuit AnalysisMagnetic ComponentsMagnetization ProcessesCore Loss AnalysisCore LossesEddy Current LossesFinite Element ModelingHysteresis LossesMagnetic Field DistributionMagnetic Hysteresis ModelingMagnetic Losses
Dynamic hysteresis loop shapes and magnetic power losses are studied in nonoriented Fe-Si laminations exhibiting significant excess losses. Measurements are carried out under controlled sinusoidal induction in the frequency range from 1 Hz to 1.6 kHz, at various peak inductions from 0.25 to 1.5 T. Excess losses are found to obey a f3/2 law up to frequencies of 200–400 Hz, depending on peak induction. Beyond this limit, definite deviations are observed, due to eddy current shielding. Detailed information on the flux and field distribution in this high frequency regime is obtained by finite element solutions of Maxwell equations employing the dynamic Preisach model to describe quasi-static hysteresis and dynamic wall processes. The agreement between theoretical predictions and measurements is discussed.
9