Physics in Medicine and Biology · 1978 · 137 citations · 16 references
MedicineNuclear EngineeringPhysicsPhotonicsRadiation ProtectionRadiation TransportElectron Beam PhysicsElectron DosimetryStopping PowerElectron Stopping PowerMass Stopping PowerNuclear Stopping PowerStopping Power Of Water
Water/air mass stopping power ratios have been calculated for 5, 10, 20 and 30 MeV electron beams and various photon beams from 60Co to 31 MV betatron. The stopping power ratios have been evaluated by applying a modified version of the Spencer-Attix theory to depth-dependent electron flux spectra computed by the Monte Carlo method. Results are presented for three values of the cavity size parameter delta, 0.001, 0.01 and 0.1 MeV, and also for a Bragg-Gray cavity. For the electron beams, the results are compared to Berger's comprehensive computations. In the case of the photon beams, such a rigorous evaluation of the stopping power ratio has not been carried out previously. It is shown that the currently used approximate Bragg-Gray ratios are as much as 2% too low for high energy photon beams, and that there is a difference of about 1% between values for betatron (thin target) and linac (thick target) beams of the same maximum photon energy.
16
The Density Effect for the Ionization Loss in Various Materials
R. M. Sternheimer · Physical Review · 1952 · 389 citations
L. V. Spencer, F.H. Attix · Radiation Research · 1955 · 333 citations
A General Theory of Cavity Ionisation
T. E. Burlin · British Journal of Radiology · 1966 · 192 citations
Some Physical Aspects of Relative Biological Efficiency
P.R.J. Burch · British Journal of Radiology · 1957 · 53 citations