Study on the potential use of helical swirl generators in enhancing the thermal performance of solar air heaters

Mohanad Hasan

International Journal of Ambient Energy · 2009 · 10 citations · 23 references

Concepts

Abstract

SYNOPSIS The thermal performance of a solar air heater may be enhanced by means of twisted tapes, inserted inside the fluid flow tubes, which induce swirl flow acting as turbulence promoters. Experiments were carried out to investigate the effect of helical tape inserts of two different twist ratios (23 and 11) on the friction factor and heat transfer coefficient for a flow in a circular tube maintained at uniform heat flux conditions. The data were recorded at low Reynolds numbers, well in the turbulent region, for a wide range, 8.05 × 103 − 1.36 × 104. The results confirm that this system with helical tape inserts could enhance heat transfer by about 1. 15 to 1.7 times compared to that of plain tube. Also, the study shows that higher heat transfer rates were recorded for lower twist ratios.

References

23