The quantitative sonographic measurements had an excellent diagnostic performance for lateral epicondylitis, as well as good or excellent interreader agreement. A common extensor tendon cross-section area greater than or equal to 32 mm(2) and a thickness of 4.2 mm correlated well with the presence of lateral epicondylitis. However, further prospective study is necessary to determine whether quantitative ultrasound with these cutoff values can improve the accuracy of the diagnosis of lateral epicondylitis.