Two-Phase Flow Splitting at Side-Branching Tees

Suzanne Griston, Jai Hyun Choi

SPE Western Regional Meeting · 1998 · 14 citations · 11 references

Concepts

Abstract

Abstract The primary function of a steam distribution system is to deliver uniform-quality steam at the desired rates to each injection well within a steamflood project area. Historically, the distribution system has included either side-branching or impacting tees to split the steam. However, both of these standard pipe junctions have been found to be inadequate for the distribution of two-phase steam. Field tests were conducted to evaluate steam flow splitting through side-branching tees with and without a reduced diameter side-branch. The main objective was to obtain a better understanding of two-phase flow splitting at side-branching tees over a wide range of steam conditions. In addition, tests were conducted to evaluate the performance of modified side-branching tee designs. This paper presents field test results for several different side-branching tee configurations, compares test results to other published studies, and discusses the relative merits and limitations of side-branching tees for steam flow splitting.

References

11