<i>In situ</i>x-ray diffraction study of silicon at pressures up to 15.5 GPa and temperatures up to 1073 K

G. A. Voronin, Cristian Pantea, T. W. Żerda, Liping Wang, Yusheng Zhao

Physical review. B, Condensed matter · 2003 · 76 citations · 18 references

Concepts

Abstract

In situ x-ray diffraction measurements of silicon were conducted in the pressure range 6--15.5 GPa and at temperatures up to 1073 K. The results were used to improve the phase diagram for silicon. The pressure range where the ${\mathrm{Si}}_{\mathrm{II}}$ phase is stable in the temperature interval 293--973 K was found. The positions of the ${\mathrm{Si}}_{\mathrm{I}}\ensuremath{-}{\mathrm{Si}}_{\mathrm{II}},$ ${\mathrm{Si}}_{\mathrm{II}}\ensuremath{-}{\mathrm{Si}}_{\mathrm{XI}},$ ${\mathrm{Si}}_{\mathrm{XI}}\ensuremath{-}{\mathrm{Si}}_{\mathrm{V}}$ equilibrium lines and the ${\mathrm{Si}}_{\mathrm{I}}\ensuremath{-}{\mathrm{Si}}_{\mathrm{II}}\ensuremath{-}{\mathrm{Si}}_{\mathrm{L}},$ ${\mathrm{Si}}_{\mathrm{II}}\ensuremath{-}{\mathrm{Si}}_{\mathrm{XI}}\ensuremath{-}{\mathrm{Si}}_{\mathrm{L}},$ ${\mathrm{Si}}_{\mathrm{XI}}\ensuremath{-}{\mathrm{Si}}_{\mathrm{V}}\ensuremath{-}{\mathrm{Si}}_{\mathrm{L}}$ triple points were determined.

References

18