Vox Sanguinis · 1984 · 59 citations · 10 references
MedicineImmunologyPediatricsClinical ImmunologyNeonatologyPediatric ImmunologyHemolytic DisordersNeonatal ImmunologyRed Blood Cell DisordersClinical Outcome MeasurementNeonatal Hemolytic Disease
An in vitro test system is described which measures the ability of anti-D sera to lyse Rh(D)-positive red cells. This test was applied to anti-D sera from 11 cases of HDN selected in Glasgow and tested 'blind' in Edinburgh. Evidence is presented to support the view that the ADCC (antibody-dependent cell-mediated cytotoxicity ) assay can correctly identify those cases where there is a satisfactory clinical outcome despite a high level of anti-D suggesting otherwise. Amniocentesis might therefore be avoided in this group.
10
Maternal anti-D concentrations and outcome in rhesus haemolytic disease of the newborn.
P. J. BOWELL, J. S. Wainscoat, Tim Peto et al. · BMJ · 1982 · 95 citations · Full text
S. J. Urbaniak, M. Ayoub Greiss · British Journal of Haematology · 1980 · 48 citations