Resorbable PLLA-PGA Screw Fixation of Mandibular Sagittal Split Osteotomies

Richard C. Edwards, Kevin D. Kiely, Barry L. Eppley

Journal of Craniofacial Surgery · 1999 · 44 citations · 0 references

Concepts

Abstract

The purpose of this study was to evaluate the intraoperative placement and clinical effectiveness of resorbable copolymeric screws for mandibular sagittal split ramus osteotomies. Thirty-seven patients who underwent bilateral sagittal split osteotomies of the mandible were fixated with three 2.5-mm copolymeric poly-L-lactic-polyglycolic (PLLA-PGA) screws on each side. No postoperative maxillomandibular fixation was applied. Twenty-five patients experienced mandibular advancement and 12 patients had setbacks. The average advancement was 6.5 mm (range, 3-17 mm) and the average set-back was 5.2 mm (range, 3-8 mm). Intraoperative placement was uncomplicated and no screws were stripped during placement. No problems in immediate postoperative stability were encountered and relapse was not evident in any patient. Follow-up ranged from 3 to 17 months. The screw holes remained evident radiographically after 1 year. Two and one-half-millimeter copolymeric PLLA-PGA resorbable screws for mandibular ramus osteotomies appear to offer clinical results comparable with metallic screw fixation.