MedicineRadiologyDiagnostic ImagingDiagnostic RadiologyThoracic ImagingChest RadiologyComputed TomographyMedical ImagingPositron Emission TomographyThoracic Oncology ImagingInspiratory Computed TomographyPet QuantificationPet-computed TomographyThoracic Mass EvaluationTumor Volume EstimationTumor Volume MeasurementWhole-body Computed TomographyWhole-body Pet Imaging
OBJECTIVE: The aim of this study was to determine the optimal acquisition scan protocol for deep inspiration breath-hold (BH) fluoro-2-deoxy-D-glucose positron emission tomography (PET) for the examination of thoracic lesions. METHODS: We studied 32 thoracic lesions in 21 patients. Whole-body PET/computed tomography (CT) scanning with free breathing (FB) was performed for 3 min per bed position, followed by a BH-CT and five BH-PET for 20 s each. Summed BH images with total acquisition times of 40, 60, 80 and 100 s were generated (BH × 2, BH × 3, BH × 4 and BH × 5, respectively). The displacements between PET and CT images, the lesion volume of the PET image, the maximum standardized uptake value (SUVmax) and the quality of the PET image were assessed in relation to the clinical characteristics of each patient and the summation of the BH-PET images. RESULTS: BH-PET decreased the tumor volume significantly (FB: 7.23 ± 9.70 cm³, BH × 5: 4.71 ± 5.14 cm³, P<0.01) and increased the SUVmax (FB: 6.27 ± 5.41, BH × 5: 7.53 ± 6.28, P<0.01). The displacement between the PET and CT images was improved significantly in the BH scans (FB: 0.77 ± 0.53 cm, BH × 5: 0.36 ± 0.24 cm, P<0.01). In addition, aging and lung function of patients influenced the reproducibility of BH-PET. The summed BH-PET images, obtained by summation of three or more BH-PET images (total acquisition time of 60 s or more), achieved good image quality. CONCLUSION: BH-PET/CT improved the misregistration between PET and CT images and increased the SUVmax of thoracic lesions. The recommended number of BH-PET images for summation with 20 s of acquisition time is three or more.
26
A combined PET/CT scanner for clinical oncology.
Thomas Beyer, D.W. Townsend, T. Brun et al. · PubMed · 2000 · 1.6K citations
4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT
Tinsu Pan, Ting-Yim Lee, Eike Rietzel et al. · Medical Physics · 2004 · 620 citations
Benefit of Time-of-Flight in PET: Experimental and Clinical Results
Joel S. Karp, Suleman Surti, Margaret E. Daube-Witherspoon et al. · Journal of Nuclear Medicine · 2008 · 584 citations · Full text
Joern Wulf, Ulrich Haedinger, Ulrich Oppitz et al. · International Journal of Radiation Oncology*Biology*Physics · 2004 · 351 citations