RSC Advances · 2013 · 106 citations · 45 references
EngineeringBioengineeringBiomedical EngineeringBiomemsBiosensorsSensorsEnzyme-based BiosensorsFluorescence ImagingMicrofluidic BiosensorsMicrofluidic DevicesMicrofluidicsPoint-of-care BiosensingFluorescence-based AssaysFluorescent SensorsMicrofluidic Device DesignMicrofluidic Enzymatic BiosensorsPaper-based Analytical DevicesPaper-based Diagnostic DevicesPaper-based Enzymatic BiosensorsPaper-based Microfluidic Biosensors
Fluorescence assays typically require specialized equipment, limiting their use in resource‑constrained settings. The authors present a point‑of‑care assay that uses visible‑region fluorescence captured by a camera‑equipped cell phone to quantify enzyme biomarkers, and they characterize the design parameters that influence sensitivity and reproducibility. The assay employs a paper‑based microfluidic device containing an internal fluidic battery, a surface‑mounted LED, a 2‑mm clear‑straw cuvette, and a small‑molecule reagent that becomes highly fluorescent upon enzyme binding, and the resulting fluorescence is photographed by a phone camera and quantified via image‑processing software. In a 30‑minute test, the system quantified β‑D‑galactosidase down to 700 p.
Fluorescence assays often require specialized equipment and, therefore, are not easily implemented in resource-limited environments. Herein we describe a point-of-care assay strategy in which fluorescence in the visible region is used as a readout, while a camera-equipped cellular phone is used to capture the fluorescent response and quantify the assay. The fluorescence assay is made possible using a paper-based microfluidic device that contains an internal fluidic battery, a surface-mount LED, a 2-mm section of a clear straw as a cuvette, and an appropriately-designed small molecule reagent that transforms from weakly fluorescent to highly fluorescent when exposed to a specific enzyme biomarker. The resulting visible fluorescence is digitized by photographing the assay region using a camera-equipped cellular phone. The digital images are then quantified using image processing software to provide sensitive as well as quantitative results. In a model 30 min assay, the enzyme β-D-galactosidase was measured quantitatively down to 700 pM levels. This Communication describes the design of these types of assays in paper-based microfluidic devices and characterizes the key parameters that affect the sensitivity and reproducibility of the technique.
45
Andres W. Martinez, Scott T. Phillips, Emanuel Carrilho et al. · Analytical Chemistry · 2008 · 1.4K citations · Full text