Circulation · 1997 · 75 citations · 15 references
MedicineCardiologySurgeryCardiothoracic SurgeryClinical CardiologyVascular SurgeryCardiac Valve SurgeryEndovascular SurgeryMinimally Invasive Cardiothoracic SurgeryThoracic SurgeryCarotid Artery DopplerIntraoperative Transesophageal EchocardiographyInvasive Cardiac MonitoringMinimally Invasive Mitral Valve SurgeryPort-access Cardiac SurgeryTransesophageal Echocardiography Hemodynamics
BACKGROUND: A method for monitoring patients was evaluated in a clinical trial of minimally invasive port-access cardiac surgery with closed chest endovascular cardiopulmonary bypass. METHODS AND RESULTS: Cardiopulmonary bypass was conducted in 25 patients through femoral cannulas. An endovascular pulmonary artery vent was placed in the main pulmonary artery through a jugular vein. For mitral valve surgery, a catheter was placed in the coronary sinus for delivery of cardioplegia. A balloon catheter ("endoaortic clamp," EAC) used for occlusion of the ascending aorta, delivery of cardioplegia, aortic root venting, and pressure measurement was inserted through a femoral artery and initially positioned by use of fluoroscopy and transesophageal echocardiography (TEE). Potential migration of the EAC was monitored by (1) TEE of the ascending aorta, (2) pulsed-wave Doppler of the right carotid artery, (3) balloon pressure, (4) comparison of aortic root pressure and right radial artery pressure, and (5) fluoroscopy. TEE, fluoroscopy, and pressure measurement were effective in monitoring catheter insertion and position. With inadequate balloon inflation, migration of the EAC toward the aortic valve could be detected with TEE. During administration of cardioplegia, TEE showed movement of the balloon away from the aortic valve, and migration into the aortic arch was detectable with loss of carotid Doppler flow. Stability of EAC position was demonstrated with appropriate balloon volume. Cardioplegic solution was visualized in the aortic root, and aortic root pressure changed appropriately during administration of cardioplegia. Venous cannula position was optimized with TEE and endopulmonary vent flow measurement. CONCLUSIONS: An effective method has been developed for monitoring patients and the catheter system during port-access cardiac surgery.
15
Direct Myocardial Revascularization without Extracorporeal Circulation
Federico Benetti, Gandolfo Naselli, Michael Wood et al. · CHEST Journal · 1991 · 571 citations
Medicine, Cardiology, Surgery +9
Minimally invasive coronary artery bypass grafting
Tea E. Acuff, Rodney J. Landreneau, Bartley P. Griffith et al. · The Annals of Thoracic Surgery · 1996 · 299 citations
Medicine, Cardiology, Surgery +8
Daniel Schwartz, Greg H. Ribakove, Eugene A. Grossi et al. · Journal of Thoracic and Cardiovascular Surgery · 1996 · 134 citations · Full text
Medicine, Cardiology, Surgery +10