Abstract

Endovascular stent grafts can be placed emergently. Commercial grafts result in better results than noncommercial grafts. Available "cuff extenders" are sufficient for the majority of aortic injuries but often require deployment via the iliac or aorta because of the shorter delivery system. Tears more than 1.5 cm resulting in apposition length less than 2 cm or those near or in the curvature of the aorta are associated with increased endoleak risk. The ideal thoracic EVSG would be available in 5-, 7.5-, 10-, and 15-cm lengths and mounted on a system 80 cm in length.