Anesthesia & Analgesia · 2005 · 238 citations · 17 references
MedicineAnesthesiologySurgeryAnesthesiaLaryngologyThoracic ImagingAirway AssessmentAirway ImagingCervical Spine ExaminationEndotracheal IntubationMechanical VentilationCervical Motion SegmentsCervical Spine EvaluationCervical Spine MotionEndotracheal Intubation TimingFluoroscopic Airway EvaluationFluoroscopic GuidanceMotion Segment AnatomyThoracic Motion Segments
In Brief The question of which is the optimum technique to intubate the trachea in a patient who may have a cervical(C)-spine injury remains unresolved. We compared, using fluoroscopic video, C-spine motion during intubation for Macintosh 3 blade, GlideScope®, and Intubating Lighted Stylet, popularly known as the Lightwand or Trachlight®. Thirty-six healthy patients were randomized to participate in a crossover trial of either Lightwand or GlideScope to Macintosh laryngoscopy, with in-line stabilization. C-spine motion was examined at the Occiput-C1 junction, C1-2 junction, C2-5 motion segment, and C5-thoracic motion segment during manual ventilation via bag-mask, laryngoscopy, and intubation. Time to intubate was also measured. C-spine motion during bag-mask ventilation was 82% less at the four motion segments studied than during Macintosh laryngoscopy (P < 0.001). C-spine motion using the Lightwand was less than during Macintosh laryngoscopy, averaging 57% less at the four motion segments studied (P < 0.03). There was no significant difference in time to intubate between the Lightwand and the Macintosh blade. C-spine motion was reduced 50% at the C2-5 segment using the GlideScope (P < 0.04) but unchanged at the other segments. Laryngoscopy with GlideScope took 62% longer than with the Macintosh blade (P < 0.01). Thus, the Lightwand (Intubating Lighted Stylet) is associated with reduced C-spine movement during endotracheal intubation compared with the Macintosh laryngoscope. IMPLICATIONS: The question of which is the optimum technique to intubate the trachea of a patient who may have a cervical(C)-spine injury remains unresolved. Using fluoroscopic video, C-spine motion during intubation was compared for Macintosh 3 blade, GlideScope, and Lightwand use. The Lightwand is associated with reduced C-spine movement during intubation compared to Macintosh laryngoscope.
17
Difficult tracheal intubation in obstetrics
R. S. Cormack, J. R. Lehane · Anaesthesia · 1984 · 2.5K citations
Medicine, Anesthesiology, Obstetrics +10
Cervical Spine Motion with Direct Laryngoscopy and Orotracheal Intubation
Paul D. Sawin, Michael M. Todd, Vincent C. Traynelis et al. · Anesthesiology · 1996 · 198 citations · Full text
Clinical Trial of a New Lightwand Device (Trachlight) to Intubate the Trachea
Orlando Hung, Saul Pytka, Ian R. Morris et al. · Anesthesiology · 1995 · 190 citations · Full text
Medicine, Anesthesiology, Surgery +12