Radiology · 1969 · 17 citations · 4 references
MedicineNuclear MedicineRadiologyDiagnostic Nuclear MedicineNuclear ChemistryRenal Nuclear MedicineNuclear Medicine ChemistryNuclear Medicine ImagingRenal Function TestsRenal ImagingRenal Nuclear ImagingRenal ScintigraphyGlomerular Filtration Rate MeasurementGlomerular Filtration Rate TracersQuantitative Renal ScintigraphyRenal Nuclear ScintigraphyScintillationTechnetium-99m Diethylenetriamine Pentaacetic Acid RenographyTechnetium-99m Diethylenetriaminepentaacetic Acid Renography
PHYSIOLOGICALLY stable metal chelates are usually excreted by glomerular filtration. We have previously reported that short-lived indium 113m chelated with diethylenetriaminepentaacetic acid is potentially useful for studies of kidney, that is, for the measurement of glomerular filtration rate, renogram studies, and kidney scans (8). Subsequently, we developed ytterbium-169-DTPA complex (4) which has a longer half-life and can also be used for renal studies (5). Preliminary studies on the use of these chelates to visualize both renal structure and function with the help of a scintillation camera were reported at the 1968 meeting of the Society of Nuclear Medicine (9). Recently, Hisada et al. (3) have also used 113,mIn-DTPA complex for similar studies. Other useful chelates include the long-lived 51Cr-DTPA complex (2) and the short-lived 68Ga-EDTA complex (7). Relative whole-body radiation doses were considered for the use of the chelates labeled with 68Ga, 113mIn, 51Cr, and 169Yb in normal subjects as well as in patients with severe renal insufficiency. The quality of scan images obtained with currently available detection equipment depends primarily on the physical characteristics of the radionuclide and the photon flux. Generally, nuclides emitting gamma rays of 100–300 keV are more suitable for scanning and camera imaging. The high photon flux is required for rapid scanning, and multimil-licurie amounts are administered. The purpose of the present report is to describe our experience with the use of high photon chelates of 113mIn and 169Yb in renal scanning. Method And Results Radiopharmaceuticals 113mIn-DTPA was prepared in a manner described by Stern et al. (11). Approximately 20 mCi of 113mIn was eluted with 0.05 N HCI; 100 µg Fe of FeCl3, and 1 mg of DTPA was added; the solution was made isotonic; the pH was adjusted to 6; and the final product was sterilized and used soon. 169Yb-DTPA was prepared by the method of Hosain et al. (4). Twenty mCi of 169Yb in the form YbCl3 of high specific activity was diluted in 0.0.5 N HCI; 10 mg of DTPA was added; the solution was made isotonic; the pH was adjusted to 6; and the final product was sterilized, stored, and used. Initial studies were carried out in dogs and were extended to human subjects using a rectilinear scanner and a gamma camera. Rectilinear Scans Serial scans of the kidneys and bladder were performed with a rectilinear scanner after intravenous injections of 3–5 mCi of 113mIn-DTPA and 169Yb-DTPA in dogs.
4
Ytterbium-169 Diethylenetriaminepentaacetic Acid Complex
Fazle Hosain, Richard C. Reba, Henry N. Wagner · Radiology · 1968 · 32 citations