EngineeringCivil EngineeringFinite Element AnalysisSeismic DesignStructural EngineeringReinforced Concrete StructuresSteel StructuresStructural DesignStructural MechanicsStructural Response AnalysisStructural SystemsBeam ModellingBeam-column ConnectionsFailure ModesMoment ConnectionsReinforced Concrete Frame StructuresSeismic Design CodesSteel Moment FramesStructural Framing Systems
The assemblies represent portions of structural framing systems designed as intermediate moment frames (IMFs) and special moment frames (SMFs) for Seismic Design Categories C and D, respectively. The study experimentally and computationally evaluates steel and reinforced concrete beam‑column assemblies under monotonic vertical displacement of a center column to simulate a column removal scenario. The assemblies were designed per ANSI/AISC 341‑02 and ACI 318‑02, with prequalified moment connections from FEMA 350, and each full‑scale unit contains two beam spans and three columns; detailed and reduced finite‑element models were developed to capture primary response characteristics and failure modes. The study reveals the behavior and failure modes of the assemblies, including catenary action, and shows that reduced finite‑element models can be executed rapidly without loss of accuracy, enabling their use in whole‑system analyses.
This paper presents an experimental and computational assessment of the performance of steel and reinforced concrete beam-column assemblies under monotonic vertical displacement of a center column, simulating a column removal scenario. The assemblies represent portions of structural framing systems designed as intermediate moment frames (IMFs) and special moment frames (SMFs) for Seismic Design Categories C and D, respectively. The steel IMF and SMF assemblies were designed in accordance with ANSI/AISC 341-02 by using prequalified moment connections specified in FEMA 350. The concrete IMF and SMF assemblies were designed and detailed in accordance with ACI 318-02 requirements. Each full-scale assembly comprises two beam spans and three columns, and downward displacements of the center column are imposed until failure. The study provides insight into the behavior and failure modes of the assemblies, including the development of catenary action. Both detailed and reduced finite-element models are developed, which capture the primary response characteristics and failure modes. Analyses with the reduced models can be executed rapidly without loss of accuracy, facilitating implementation in models of entire structural systems.
3
Minimum Design Loads for Buildings and Other Structures
Edward Cohen · 1990 · 1.4K citations
Recommended Seismic Design Criteria for New Steel Moment-Frame Buildings
Ronald O. Hamburger, John Hooper, Thomas A. Sabol et al. · 2000 · 779 citations