Corrosion prevention and control at Sellafield nuclear fuel reprocessing plant

Ruth Shaw

British Corrosion Journal · 1990 · 24 citations · 0 references

Concepts

Abstract

AbstractAfter discharge from the reactor and transport to Sellafield, irradiated nuclear fuels are stored in water filled ponds before being reprocessed. BNFL has established fuel management strategies and a pond water chemistry which ensures minimal corrosion of stored fuels. BNFL's materials selection policy for its reprocessing plants has developed from over 35 years' experience with Magnox reprocessing. An extensive R&D programme evaluated materials for the thermal oxide reprocessing plant (Thorp). The original stainless steels used in Magnox reprocessing plants, 18Cr–13Ni–Nb and 18Cr– 8Ni–Ti, have been observed to show deficiencies in operation such as end grain corrosion, knifeline attack at welds, susceptibility to corrosion in HNO3 vapours, and poor resistance to iodine vapour corrosion. Titanium plant has also shown corrosion performance deficiencies. For Thorp, nitric acid grade 18–10L and 304L stainless steels have replaced 18–13–Nb and 18–8–Ti respectively, whereas 310L has been used to constr...