The Journal of Advanced Prosthodontics · 2014 · 21 citations · 34 references
DentistryDental Biomaterials ScienceDental Materials ScienceDental MaterialsDigital ProsthodonticsSurface Properties Of Dental MaterialsComputer-aided Design In ProsthodonticsDenture ProcessingDigital Dental ImagingDigital Denture FabricationDigital Impression TechniquesImpression MaterialsCad And Cam Dental MaterialsCad-cam Denture FabricationComputer-aided Denture FabricationDental DiscrepancyDigital Impression SystemsDigital Impressions For DenturesOptical ScanningZirconia
PURPOSE: This study aimed to investigate the potential clinical application of digitized silicone rubber impressions by comparing the accuracy of zirconia 3-unit fixed partial dentures (FPDs) fabricated from 2 types of data (working model and impression) obtained from a laser scanner. MATERIALS AND METHODS: Ten working models and impressions were prepared with epoxy resin and vinyl polysiloxane, respectively. Based on the data obtained from the laser scanner (D-700; 3Shape A/S, Copenhagen, Denmark), a total of 20 zirconia frameworks were prepared using a dental CAD/CAM system (DentalDesigner; 3shape A/S, Copenhagen, Denmark / Ener-mill, Dentaim, Seoul, Korea). The silicone replicas were sectioned into four pieces to evaluate the framework fit. The replicas were imaged using a digital microscope, and the fit of the reference points (P1, P2, P3, P4, P5, P6, and P7) were measured using the program in the device. Measured discrepancies were divided into 5 categories of gaps (MG, CG, AWG, AOTG, OG). Data were analyzed with Student's t-test (α=0.05), repeated measures ANOVA and two-way ANOVA (α=0.05). RESULTS: The mean gap of the zirconia framework prepared from the working models presented a narrower discrepancy than the frameworks fabricated from the impression bodies. The mean of the total gap in premolars (P=.003) and molars (P=.002) exhibited a statistical difference between two groups. CONCLUSION: The mean gap dimensions of each category showed statistically significant difference. Nonetheless, the digitized impression bodies obtained with a laser scanner were applicable to clinical settings, considering the clinically acceptable marginal fit (120 µm).
34
The estimation of cement film thickness by an in vivo technique
J W McLean, Fraunhofer von · BDJ · 1971 · 1.4K citations
Clinical fit of Procera AllCeram crowns
Klaus Boening, Burkhard H. Wolf, Annette Schmidt et al. · Journal of Prosthetic Dentistry · 2000 · 286 citations