Advanced HatSteam DistributionEngineeringEnergy EfficiencyMechanical EngineeringStirling EngineCompressorGas Turbine CombustionConversion SystemEfficiency ImprovementFluid MachineryWind Turbine ModelingHeat TransferGas Turbine EngineWater AtomizationWater RecoveryRefrigeration
The AHAT (Advanced HAT) system can be used for single shaft gas turbines without redesigning them and it gives a similar effect as intercooling by using suction air atomization. In this paper, two basic experiments with a spray nozzle, simplified humidifier and water recovery were carried out. A compact heat exchanger for humidified gas turbines could be realized by using the spray nozzle without significant pressure loss. In addition, a big effect was found in the efficiency improvement when water atomization into the compressor was combined with the regenerative cycle. The AHAT system had high efficiency, 5% higher compared with the mid-size combined cycle.