Optics Letters · 1993 · 94 citations · 17 references
EngineeringBiomedical EngineeringBiophysicsBiomedical ImagingBiomedical OpticsOpticsLaser-tissue InteractionLight-tissue InteractionOptical Coherence TomographyOptical ImagingOptical TomographyTissue OpticsDynamic RangeFemtosecond Laser PulsesFemtosecond Laser SourcesHeterodyne DetectionHeterodyne InterferometryHigh-resolution ImagingImaging ResolutionOptical Coherence Tomography Instrumentation
We describe diffuse-light time-gated imaging with transillumination optical coherence tomography. Submillimeter-resolution imaging of objects hidden in thick biological tissue is achieved in cases in which ballistic light is absent by selecting only the early-arriving coherent portion of the diffuse transmitted light. By using a femtosecond laser as a high-power low-coherence light source, we perform high-sensitivity (130-dB dynamic range) optical gating with interferometric heterodyne detection. The dependence of image resolution on coherent photon arrival time is investigated in model scattering media.
17
David Huang, Eric A. Swanson, Charles P. Lin et al. · Science · 1991 · 13.7K citations
Ballistic 2-D Imaging Through Scattering Walls Using an Ultrafast Optical Kerr Gate
L. Wang, P. P. Ho, C. Liu et al. · Science · 1991 · 550 citations
Time-resolved transillumination for medical diagnostics
Stefan Andersson‐Engels, O. Jarlman, Roger Berg et al. · Optics Letters · 1990 · 257 citations · Full text
Optical Time-of-Flight and Absorbance Imaging of Biologic Media
David A. Benaron, David K. Stevenson · Science · 1993 · 230 citations