Publication | Closed Access
Induced current densities from low-frequency magnetic fields in a 2 mm resolution, anatomically realistic model of the body
145
Citations
10
References
1998
Year
EngineeringRealistic ModelCurrent DensityMagnetic ResonanceAnatomical ModelMm ResolutionMagnetic Resonance ImagingElectrophysiological EvaluationKinesiologyVoxel PhantomMagnetohydrodynamicsComputational ElectromagneticsInduced Current DensitiesComputational AnatomyRadiologyHealth SciencesHuman BodyMedical ImagingMagnetic MeasurementNeuroimagingBrain ImagingMicro-magnetic ModelingNeurophysiologyPhysiologyBiomedical ImagingNeuroscienceElectrophysiologyMagnetic Field
This paper presents calculations of current density in a fine-resolution (2 mm) anatomically realistic voxel model of the human body for uniform magnetic fields incident from the front, side and top of the body for frequencies from 50 Hz to 10 MHz. The voxel phantom, NORMAN, has a height of 1.76 m and a mass of 73 kg. There are 8.3 million voxels in the body differentiated into 37 tissue types. Both the impedance method and the scalar potential finite difference method were used to provide mutual corroboration. Results are presented for the current density averaged over 1 cm2 in muscle, heart, brain and retina.