Publication | Closed Access
Biomechanical evaluation of different suture materials for arthroscopic transtibial pull‐out repair of posterior meniscus root tears
74
Citations
53
References
2013
Year
None of the evaluated suture materials provided clearly superior properties over the others during both cyclic loading and load-to-failure testing. Based on the results of this study, FiberWire™ may be the preferred suture material for transtibial pull-out repair of posterior meniscus root tears because of comparably low displacement during cyclic loading and high values for maximum load and stiffness. In the clinical setting, FiberWire™ may improve healing rates and avoid progressive extrusion of the meniscus after transtibial pull-out repair of posterior meniscus root tears.