Otolaryngology · 1998 · 30 citations · 6 references
MedicineNeurosurgerySurgeryBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyFluoroscopy-guided ProceduresPituitary ImagingPituitary SurgeryPituitary TumorsImage-guided NeurosurgeryIntraoperative VisualizationPituitary Lesion ImagingPituitary Region ImagingPituitary Tumor DelineationSpatial Anatomical RelationshipsSurgical Field ExposureSurgical Site Exposure
OBJECTIVE: Advances in imaging resolution have resulted in superior visualization of intracranial anatomy. Because of the inherent complexity of the surgical exposure of these lesions, intraoperative localizing techniques are required. Currently, C-arm fluoroscopy provides only two-dimensional localization for these anatomic structures. The recently described ACUSTAR I system, developed in conjunction with Codman and Shurtleff, Inc. (Randolph, Mass.), is an interactive, image-guided device that allows three-dimensional localization with a degree of accuracy previously unattainable. We assessed the clinical utility of the ACUSTAR I system for intraoperative spatial confirmation during transsphenoidal approaches to pituitary lesions. METHODS: Eight patients underwent transsphenoidal approaches to pituitary lesions with the assistance of the ACUSTAR I system. The spatial relationships were clinically judged intraoperatively by the surgeon and by use of traditional C-arm fluoroscopy and then were compared with the ACUSTAR I system results. RESULTS: In all eight patients, the ACUSTAR I system correctly displayed the surgical orientation and provided localization to within less than 1 mm. In two patients, this facilitated the redirection of an errant approach. No complications were associated with the use of this image-guided device. CONCLUSIONS: The ACUSTAR I system is useful in displaying accurate, three-dimensional anatomic relationships during transsphenoidal approaches to pituitary lesions. This system provides critical information intraoperatively to redirect errant approaches and prevent significant morbidity.
6
The Application Accuracy of Stereotactic Frames
Robert J. Maciunas, Robert L. Galloway, Jim Latimer · Neurosurgery · 1994 · 398 citations
A frameless, armless navigational system for computer-assisted neurosurgery
Amami Kato, Toshiki Yoshimine, Tõru Hayakawa et al. · Journal of neurosurgery · 1991 · 292 citations
Interactive Image‐Guided Neurosurgery
Robert L. Galloway, Robert J. Maciunas, Charles A. Edwards · Journal of Neuroimaging · 1995 · 204 citations
Engineering, Neurosurgery, Surgery +13
The evolution of transsphenoidal pituitary microsurgery.
Richard Welbourn · PubMed · 1986 · 78 citations
Medicine, Neurosurgery, Surgery +11