Thin-Section Computed Tomography in the Evaluation of Third Ventricular Colloid Cysts

Anne G. Osborn, S. Douglas Wing

Radiology · 1977 · 24 citations · 0 references

Concepts

Abstract

The computed tomographic (CT) scan findings in 4 cases of third ventricular colloid cyst are presented, and the importance of thin-section CT in the evaluation of this lesion is discussed. Overlapping 8-mm sections are helpful in differentiating normal vasculature adjacent to the foramen of Monro from a third ventricular colloid cyst.