Respirology · 2004 · 39 citations · 18 references
MedicineOncologyThoracic ImagingThoracic OncologyThoracic RadiologyCancer DetectionCancer DiagnosisComputed TomographyFine-needle Aspiration CytologyLung CancerThoracic Oncology ImagingCytological ExaminationImage-guided Fine-needle AspirationImage-guided Needle AspirationLung Cancer CytologyLung Fine-needle Aspiration CytologyNeedle Aspiration TechniqueTransbronchial Cytologic Sampling
OBJECTIVES: The aim of the present study was to compare single-pass needle and multiple-pass coaxial needle systems and to evaluate the value of immediate cytological assessment during the procedure in the diagnosis of lung cancer with CT-guided transthoracic fine-needle aspiration. METHODOLOGY: One hundred and forty-three consecutive patients who underwent CT-guided transthoracic fine-needle aspiration were divided into three groups. In the first group (group A, 48 patients), a single-pass needle was used for aspiration, but immediate cytological examination was not performed. In the second group (group B, 48 patients), a single-pass needle was used for aspiration and a pathologist immediately assessed the adequacy of the sample obtained. In the third group (group C, 47 patients), a multiple-pass coaxial needle was used for aspiration and a pathologist immediately assessed the adequacy of the sample obtained. RESULTS: The mean number of fine-needle aspirations was 1.25 in group A, 1.39 in group B and 1.34 in group C (group A vs group B, P = 0.08). The diagnostic accuracy was 83.3, 97.9 and 100.0%, respectively (group A vs group B, P = 0.03; group B vs group C, P > 0.05). Although immediate cytological assessment resulted in adequate samples being obtained from all patients in groups B and C, adequate samples were obtained in 41 of 48 patients (85.4%) in group A (P = 0.004). There was no statistically significant difference among the groups with respect to the rate of pneumothorax. CONCLUSIONS: A single-pass needle technique in transthoracic fine-needle aspiration is preferred because there is no significant difference between single-pass needle and multiple-pass coaxial needle systems with respect to the diagnostic accuracy and the complication rate and, in addition, the single-pass needle has a lower cost. The results of the present study suggest that immediate cytological assessment during the procedure reduces an inadequate sampling rate, thus increasing the diagnostic accuracy of the procedure.
18
Transthoracic needle aspiration biopsy of benign and malignant lung lesions
N. F. Khouri, FP Stitik, Erozan Ys et al. · American Journal of Roentgenology · 1985 · 300 citations
Difficult thoracic lesions: CT-guided biopsy experience in 150 cases.
Eric vanSonnenberg, G Casola, Müller Ho et al. · Radiology · 1988 · 291 citations
Olivier Lucidarme, Nigel Howarth, J F Finet et al. · Radiology · 1998 · 188 citations
CT-Guided Fine-Needle Aspiration Cytology of Solitary Pulmonary Nodules*
L. Santambrogio, Mario Nosotti, Nadia Bellaviti et al. · CHEST Journal · 1997 · 152 citations