IEEE Transactions on Power Apparatus and Systems · 1966 · 27 citations · 3 references
EngineeringElectrical EngineeringCircuit TheoryElectric MachinesPower ElectronicsGenerator OperationInduction MachinesMachine WindingsMagnetic Circuit AnalysisSynchronous MachinesThree-phase MachinesArmature Reaction In Synchronous MachinesArmature Reaction TheoryArmature WindingsCurrentsNonlinear Partial Differential EquationsSynchronous Generator OperationSynchronous Machine ModelingThree-phase Synchronous Machines
The usual two-reaction theory of synchronous machines yields results that neglect to take saturation into account. Based on a method developed in a companion paper [1], the radial airgap induction is found in synchronous machines when supplying balanced loads. The armature currents are considered to be distributed uniformly in the upper and lower layer of the armature windings. The partial differential equations, the boundary conditions, and the method of solution are reviewed. Numerical results are obtained for a 2750 kVA, 2300 V, 60 c/s, three-phase alternator at seven different internal power-factor angles. Calculated results compare well with tests.
3