Journal of Cataract & Refractive Surgery · 2008 · 62 citations · 27 references
Veterinary MedicineBiomedical EngineeringOphthalmologyAnterior SegmentUltrasonographyUltrasoundAnterior Segment ImagingDiagnostic UltrasonographyOcular BiometryOcular UltrasonographyOphthalmic ImagingOptical Coherence TomographyAnterior Chamber Angle ImagingAnterior Chamber BiometryCentral Anterior Chamber DepthCentral Corneal Thickness MeasurementCorneal Thickness AssessmentIntraclass CorrelationMeasurementOptical Coherence Tomography Instrumentation
PURPOSE: To determine the interchangeability of 2 anterior segment imaging systems: a very-high-frequency (VHF) ultrasound scanning system (Artemis 2, Ultralink LLC) and an optical coherence tomography (OCT) system (Visante, Zeiss). SETTING: Vissum Instituto Oftalmologico de Alicante, Alicante, Spain. METHODS: This study comprised 20 eyes without pathology or previous surgery. The anterior chamber depth (ACD), central corneal thickness (CCT), angle-to-angle distance (ATA), and the iridocorneal angle size (IAS) at the 0-degree and 180-degree positions were measured with 2 imaging techniques: VHF ultrasound scanning and OCT. Analysis of agreement and interchangeability was performed by the Bland and Altman method. In addition, each measurement was performed 3 times consecutively to determine intrasession repeatability by means of the coefficient of variation (CV) and the intraclass correlation coefficient (ICC). RESULTS: No statistically significant differences were found between imaging techniques in ACD, CCT, or ATA (P>.40). The ranges of agreement were 0.20 mm, 16.11 mum, and 0.80 mm for ACD, CCT, and ATA, respectively. Regarding IAS, no statistically significant differences were found in the nasal (P = .78) or temporal (P = .63) measurements between devices. However, the range of agreement for nasal (14.3 degrees) and temporal (14.90 degrees) values was relevant, indicating the 2 techniques cannot be used interchangeably for IAS measurement. Excellent intrasession repeatability scores were obtained (CV and ICC). CONCLUSION: The Artemis 2 and the Visante OCT systems provide equivalent and repeatable measurements of the ACD, CCT, and ATA and can be used interchangeably for these purposes.
27
A H BECKETT, M ROWLAND, P TURNER · The Lancet · 1965 · 16.9K citations
Anterior chamber width measurement by high-speed optical coherence tomography
Jason A. Goldsmith, Yan Li, Maria Regina Chalita et al. · Ophthalmology · 2005 · 219 citations · Full text