Publication | Open Access
Tussive effect of a fentanyl bolus administered through a central venous catheter
110
Citations
48
References
1990
Year
One hundred and ten male patients scheduled for coronary artery bypass grafting were allocated randomly into one of three groups. Patients in group A received fentanyl 7 micrograms/kg via a central venous catheter, those in group B were given fentanyl 7 micrograms/kg through a peripheral venous cannula, and patients in group C received sterile water via a central venous catheter. In group A, 45.9% of patients coughed after injection of fentanyl; the mean onset time from the end of fentanyl administration to the beginning of coughing was 10.6 seconds. Only one patient in group B and no patient in the control group exhibited a cough response (p less than 0.0001). We hypothesise that fentanyl can evoke the pulmonary chemoreflex.
| Year | Citations | |
|---|---|---|
Page 1
Page 1