Medical Physics · 2011 · 47 citations · 23 references
EngineeringBiomedical EngineeringRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyComputed TomographyComputed Tomography PhysicsImage QuantificationMedical ImagingRadiographic ImagingAttenuation Coefficient EstimationAttenuation Coefficient MeasurementAttenuation Coefficient ModelsComplex Refractive IndexComputed Tomography InstrumentationImage RepresentationIn Vivo TomographyPhase Information
PURPOSE: To explore the potential of grating-based x-ray phase-contrast imaging for clinical applications, a first compact gantry system was developed. It is designed such that it can be implemented into an in-vivo small-animal phase-contrast computed tomography (PC-CT) scanner. The purpose of the present study is to assess the accuracy and quantitativeness of the described gantry in both absorption and phase-contrast. METHODS: A phantom, containing six chemically well-defined liquids, was constructed. A tomography scan with cone-beam reconstruction of this phantom was performed yielding the spatial distribution of the linear attenuation coefficient μ and decrement δ of the complex refractive index. Theoretical values of μ and δ were calculated for each liquid from tabulated data and compared with the experimentally measured values. Additionally, a color-fused image representation is proposed to display the complementary absorption and phase-contrast information in a single image. RESULTS: Experimental and calculated data of the phantom agree well confirming the quantitativeness and accuracy of the reconstructed spatial distributions of μ and δ. The proposed color-fused image representation, which combines the complementary absorption and phase information, considerably helps in distinguishing the individual substances. CONCLUSIONS: The concept of grating-based phase-contrast computed tomography (CT) can be implemented into a compact, cone-beam geometry gantry setup. The authors believe that this work represents an important milestone in translating phase-contrast x-ray imaging from previous proof-of-principle experiments to first preclinical biomedical imaging applications on small-animal models.
23
L.A. Feldkamp, L. C. Davis, J. W. Kress · Journal of the Optical Society of America A · 1984 · 6.2K citations
X-ray phase imaging with a grating interferometer
Timm Weitkamp, Ana Díaz, Christian Dávid et al. · Optics Express · 2005 · 1.2K citations · Full text
Differential x-ray phase contrast imaging using a shearing interferometer
Christian Dávid, B. Nöhammer, H. H. Solak et al. · Applied Physics Letters · 2002 · 619 citations