Journal of Agricultural Engineering · 2014 · 18 citations · 4 references
AgricultureDairy ScienceCheese ScienceLactationThermal ComfortDairy ProcessingDairy ProductionHeat Stress AssessmentDairy Production SystemsHeat Stress Effects On Milk ProductionHeat Stress Impact AssessmentHeat Stress RiskMilk Production Under Heat StressRadiant TemperatureThermal Shock
The Italian dairy production is characterized by high heterogeneity. The typology quantitatively more important (80% of national production) is represented by cow’s milk cheeses (<em>Grana Padano</em> cheese, string cheese, Parmesan cheese, etc.), while the cheese from buffalo’s milk (especially string cheese such as <em>mozzarella</em>) and cheese from sheep and goats represents respectively 4% and 8% of the national dairy production, and are linked to specific regional contexts. Some phases of the cycle of milk processing occur at certain temperatures that are not comfortable for the workers also in relation to possible problems due to thermal shock. The aim of this study was to evaluate the risk of heat stress on workers operating in a dairy for processing of buffalo milk. The research was conducted at a dairy farm located in the province of Viterbo, Italy, during the spring-summer period. To carry out the research were detected major climatic parameters (air temperature, relative humidity, mean radiant temperature, air velocity) and the main parameters of the individual operators (clothing thermal insulation and the energy expenditure required from the work done by employees). Subsequently, main indices of heat stress assessment provided by the main technical standards were calculated. In particular have been calculated predicted mean vote and predicted percentage of dissatisfied in moderate thermal environments (environments in which the objective, in the design and management phases, is to achieve the thermal comfort), provided by the UNI EN ISO 7730 and the wet bulb globe temperature in severe hot environments (environments in which you must protect the health of workers) required by UNI EN ISO 27243. The results show some phases of risk from heat stress especially during times of test in which the internal air temperature exceeds the threshold of 30°C and possible solutions to improve the safety of the operators.
4
José Pérez-Alonso, Ángel Jesús Callejón Ferre, Ángel Carreño-Ortega et al. · Building and Environment · 2011 · 32 citations · Full text
Ángel Jesús Callejón Ferre, Francisco Manzano‐Agugliaro, Manuel Díaz-Pérez et al. · Applied Ergonomics · 2010 · 30 citations
Natural Sciences, Environmental Sciences, Risk Management +16