Transvaginal ultrasound measurement of cervical length in the supine and upright positions versus Bishop score in predicting successful induction of labor at term

M. Meijer‐Hoogeveen, Carolien Roos, Birgit Arabin, P. Stoutenbeek, G. H. A. Visser

Ultrasound in Obstetrics and Gynecology · 2009 · 27 citations · 29 references

DOIFull text

Open access

Abstract

Our results suggest that maternal postural change might improve the accuracy of sonographically-measured cervical length for predicting a vaginal delivery after induction of labor at term. However, our results need to be confirmed in a larger and more homogeneous population.