Circulation Cardiovascular Imaging · 2012 · 98 citations · 15 references
MedicineCardiologyRadiologyDiagnostic ImagingDiagnostic RadiologyUltrasonographyAortic ImagingAortic StenosisComputed TomographyEchocardiographic Hemodynamic AssessmentThree-dimensional ReconstructionValvular Heart Disease ImagingAortic Imaging MeasurementsAortic Regurgitation Severity AssessmentAortic Root AnatomyAortic Root AssessmentAortic Root DilationAortic Root DiseaseAortic Valve EvaluationThree-dimensional Volumetric Analysis
BACKGROUND: We tested the ability of a novel automated 3-dimensional (3D) algorithm to model and quantify the aortic root from 3D transesophageal echocardiography (TEE) and computed tomographic (CT) data. METHODS AND RESULTS: We compared the quantitative parameters obtained by automated modeling from 3D TEE (n=20) and CT data (n=20) to those made by 2D TEE and targeted 2D from 3D TEE and CT in patients without valve disease (normals). We also compared the automated 3D TEE measurements in severe aortic stenosis (n=14), dilated root without aortic regurgitation (n=15), and dilated root with aortic regurgitation (n=20). The automated 3D TEE sagittal annular diameter was significantly greater than the 2D TEE measurements (P=0.004). This was also true for the 3D TEE and CT coronal annular diameters (P<0.01). The average 3D TEE and CT annular diameter was greater than both their respective 2D and 3D sagittal diameters (P<0.001). There was no significant difference in 2D and 3D measurements of the sinotubular junction and sinus of valsalva diameters (P>0.05) in normals, but these were significantly different (P<0.05) in abnormals. The 3 automated intercommissural distance and leaflet length and height did not show significant differences in the normals (P>0.05), but all 3 were significantly different compared with the abnormal group (P<0.05). The automated 3D annulus commissure coronary ostia distances in normals showed significant difference between 3D TEE and CT (P<0.05); also, these parameters by automated 3D TEE were significantly different in abnormal (P<0.05). Finally, the automated 3D measurements showed excellent reproducibility for all parameters. CONCLUSIONS: Automated quantitative 3D modeling of the aortic root from 3D TEE or CT data is technically feasible and provides unique data that may aid surgical and transcatheter interventions.
15
Transcatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients
Craig R. Smith, Martin B. Leon, Michael J. Mack et al. · New England Journal of Medicine · 2011 · 6.3K citations · Full text
Medicine, Cardiology, Surgery +13
Multimodal Assessment of the Aortic Annulus Diameter
David Messika‐Zeitoun, Jean‐Michel Serfaty, Éric Brochet et al. · Journal of the American College of Cardiology · 2010 · 420 citations
Medicine, Anatomy, Cardiology +14
Alexander B. Willson, John G. Webb, Troy LaBounty et al. · Journal of the American College of Cardiology · 2012 · 408 citations
Medicine, Cardiology, Surgery +17
Arnold C.T. Ng, Victoria Delgado, Frank van der Kley et al. · Circulation Cardiovascular Imaging · 2009 · 372 citations
Medicine, Cardiology, Surgery +17
Aortic root and valve relationships: Impact on surgical repair
Karyn S. Kunzelman, Kathryn J. Grande, Tirone E. David et al. · Journal of Thoracic and Cardiovascular Surgery · 1994 · 283 citations · Full text
Medicine, Cardiology, Surgery +16