Acta Orthopaedica Scandinavica · 1984 · 24 citations · 17 references
Natural SciencesBioengineeringBiomedical EngineeringBiomechanicsMechanical Behavior Of MaterialsOrthopedic BiomechanicsBone BiomechanicsBone MechanicsBone PhysiologyElastic DeformationElastic PropertiesElasticity TheoryAcoustic EmissionBone ElasticityBone LoadingBone Material PropertiesCrackingDeformationMicrocrack FormationResidual Deformation
Entire diaphyseal bones from adult dogs were repeatedly loaded in torsion. The residual deformation after unloading from the non-linear deformation range was found to decrease with time. Acoustic-emission signals typical for micro-cracking were registered not only during loading in the non-linear deformation range but also during the initial phase of the following unloading. The initial torque and twist required for further micro-cracking decreased for every subsequent load-cycle, i.e. with the amount of cracking already formed. These observations are indications of visco-elastic properties of bone material.
17
K. Piekarski · Journal of Applied Physics · 1970 · 221 citations
Natural Sciences, Materials Engineering, Materials Science +17
Albert H. Burstein, John Currey, Victor H. Frankel et al. · Journal of Bone and Joint Surgery · 1972 · 209 citations
An Introduction to the Physics of Diagnostic Radiology.
Annals of Internal Medicine · 1972 · 152 citations
Natural Sciences, Physics, Radiology +12