Investigative Ophthalmology & Visual Science · 2010 · 30 citations · 21 references
MedicineAnatomyRadiologyDiagnostic ImagingDiagnostic RadiologyOcular AnatomyCross-sectional AnatomyExtraocular Muscle AnatomyExtraocular MusclesImaging AnatomyMagnetic Resonance ImagingNeuro-ophthalmic ImagingCross-sectional Muscle AreaExtraocular Muscle EnlargementInferior Rectus MuscleMuscle Fiber Cross-sectional AreaOptic Nerve Sheath Diameter MeasurementOrbital Magnetic Resonance ImagingStructural MriT1-weighted Imaging
PURPOSE: To establish the normal measurements of diameter and cross-sectional area of the Chinese extraocular muscles (EOMs) and optic nerve-sheath complex (ON) as seen on high-field (3-Tesla; 3T) magnetic resonance imaging (MRI). METHODS: Coronal 3T MRI of the orbit (TR, 700 ms; TE, 15 ms; FOV, 160 mm; matrix, 256 x 256; slice thickness, 1 mm; and slice gap, 0) was performed on 80 normal Chinese volunteers. T1-weighted images were analyzed with computer-assisted segmentation. The diameter and the cross-sectional area of EOMs and the ON were measured from the image plane at the posterior aspect of the globe and at 7 mm behind the globe. The maximum diameter of EOM was measured from their respective reconstructed images. RESULTS: The normal measurement (mean +/- SD) of diameter at the posterior aspect of the globe: medial rectus (MR), 3.6 +/- 0.4 mm; inferior rectus (IR), 3.7 +/- 0.8 mm; lateral rectus (LR), 2.3 +/- 0.5 mm; superior oblique (SO), 2.4 +/- 0.6 mm; and the ON, 5.4 +/- 0.7 mm. The normal measurement of diameter 7 mm behind the globe: MR, 3.2 +/- 0.6 mm; IR, 3.9 +/- 0.8 mm; LR, 4.0 +/- 0.8 mm; SO, 2.2 +/- 0.7 mm; and ON, 4.2 +/- 0.5 mm. The normal measurement of cross-sectional area at the posterior aspect of the globe: superior muscle group (SMG), 28.2 +/- 6.5 mm(2); MR, 25.5 +/- 3.2 mm(2); IR, 26.9 +/- 7.2 mm(2); LR, 17.3 +/- 3.9 mm(2); SO, 10.5 +/- 3.5 mm(2); and ON, 27.6 +/- 6.1 mm(2). The normal measurement of cross-sectional area 7 mm behind the globe: SMG, 24.1 +/- 6.6 mm(2); MR, 19.1 +/- 4.6 mm(2); IR, 29.5 +/- 6.6 mm(2); LR, 32.3 +/- 6.5 mm(2); SO, 9.7 +/- 3.9 mm(2); and ON, 17.1 +/- 2.9 mm(2). The normal measurement of maximum diameter: SMG, 4.8 +/- 1.1 mm; MR, 5.1 +/- 0.9 mm; IR, 5.4 +/- 1.0 mm; and LR, 4.5 +/- 0.9 mm. CONCLUSIONS: The Chinese 3T MRI EOMs and ON normative data may be useful in determining pathologic enlargement of the EOMs and ON in various orbital conditions. (ClinicalTrials.gov number, NCT00348413.).
21
Normative measurements of orbital structures using CT.
Ali Özgen, M. Ariyürek · American Journal of Roentgenology · 1998 · 163 citations
Medicine, Ophthalmology, Radiology +17