Analytical Chemistry · 1994 · 200 citations · 19 references
Life SciencesBioengineeringBiotechnologyBioseparationsElectroanalytical MethodsImmunotechnologyAntibody-antigen RecognitionEnzyme-linked Immunosorbent AssayImmunoassay AnalysisImmunoassay DevelopmentAntibody ImmobilizationCapture AntibodiesCapture Antibody AssaysEnzyme ImmunoassaysEnzyme-linked Immunosorbent Assay (Elisa)Immunoassay InstrumentationSandwich Enzyme-linked Immunosorbent Assay
A novel separation-free sandwich-type enzyme immunoassay for proteins is performed by designing an electrochemical detection system that enables preferential measurement of surface-bound enzyme-labeled antibody relative to the excess enzyme-labeled reagent in the bulk sample solution. In this initial model system, the assay is carried out using gold-coated microporous nylon membranes (pore size 0.2 micron) which are mounted between two chambers of a diffusion cell. The membrane serves as both a solid phase for the sandwich assay and the working electrode in the three-electrode amperometric detection system. The capture monoclonal antibody is immobilized covalently on the gold side of the membrane via a self-assembled monolayer of thioctic acid. In the separation-free sandwich assay, both model analyte protein (human chorionic gonadotropin; hCG) and alkaline phosphatase labeled anti-hCG (ALP-Ab) are incubated simultaneously with the immobilized capture anti-hCG antibody. Surface-bound ALP-Ab is spatially resolved from the excess conjugate in the bulk sample solution by introducing the enzyme substrate (4-aminophenyl phosphate) through the back side of the porous membrane. The substrate diffuses rapidly through the porous membrane where it first encounters bound ALP-Ab at the gold surface. The enzymatically generated product, aminophenol, is detected immediately by oxidation at the gold electrode (at +0.19 V vs Ag/AgCl), and the magnitude of current is directly proportional to the concentration of hCG in the sample. The response time after substrate addition is less than 1 min, although maximum response toward the analyte protein requires a sample/conjugate preincubation time of 30 min with the porous electrode.(ABSTRACT TRUNCATED AT 250 WORDS)
19
A Decade of Development in Immunoassay Methodology
J. P. Gosling · Clinical Chemistry · 1990 · 459 citations · Full text
Strategies for Electrochemical Immunoassay
William R. Heineman, H. Brian Halsall · Analytical Chemistry · 1985 · 170 citations
Homogeneous ferrocene-mediated amperometric immunoassay
Katalin di Gleria, Monika J. Green, H. Allen O. Hill et al. · Analytical Chemistry · 1986 · 131 citations