Journal of Orthopaedic Research® · 1991 · 46 citations · 24 references
MedicineOrthopaedic SurgeryOrthopedic SurgeryBiomechanicsOrthopedic BiomechanicsOrthopedicsArthroplasty BiomechanicsBone BiomechanicsBone MechanicsHip ArthroplastyHip BiomechanicsJoint MechanicsElastic StrainFemoral AnatomyHip AnatomyHip Joint LoadingHip Joint MechanicsStrain EffectsStrain RosettesTotal Hip Arthroplasty Biomechanics
Despite recent advances in total hip arthroplasty, proximal femoral resorption and osteopenia remain problems. To analyze the proximal strain effects of three different loading conditions, strains produced in intact and postarthroplasty femora have been compared. Ten adult cadaveric femora of similar size, shape, and rigidity were tested. Ten strain-gauge rosettes were positioned on each femur. To simulate the "single leg support" phase of gait, fixtures were developed to load the femora under three different configuration: the VS (vertical shaft) configuration, with a vertically orientated femur having rotational freedom proximally and distally; the ITB (iliotibial band) configuration of a femur with rotational freedom positioned 11 degrees from the vertical, with a strain-gauge adjustable metallic simulation of the lateral muscles of the thigh; and the ABD (abductor) configuration of a femur with rotational freedom positioned 11 degrees from the vertical, with a strain-gauge adjustable metallic simulation of the abductor muscles. Each femur was loaded less than or equal to 600 N through the medial point, located at one sixth of the transcondylar distance. Strain patterns and magnitudes produced by the three loading configurations were quite different in both the intact and postarthroplasty femora. Both the ITB and the ABD configurations resulted in greater proximal medial compression and lateral tension than did the VS configuration. The magnitudes of the proximal strains were significantly greater in the ABD configuration (p less than 0.05). Postarthroplasty femora showed similar proximal results. It is proposed that meaningful strain data for the physiologically loaded femur can be obtained only with simulations that include the forces produced by the iliotibial band. To overcome the indeterminate nature and biological variation in these forces, the studies have to consider a range of forces.
24
A biomechanical investigation of the human hip
Roy D. Crowninshield, Richard C. Johnston, James G. Andrews et al. · Journal of Biomechanics · 1978 · 448 citations
Iekuni Oh, William H. Harris · Journal of Bone and Joint Surgery · 1978 · 294 citations
Abduction forces in the one-legged stance
R. D. McLeish, John Charnley · Journal of Biomechanics · 1970 · 262 citations
Basic Biomechanics of the Skeletal System
H R H · Journal of Occupational and Environmental Medicine · 1981 · 231 citations
Medicine, Anatomy, Physiology +14
Stephen C. Cowin, Y. C. Fung · Journal of Biomechanical Engineering · 1982 · 213 citations · Full text
Natural Sciences, Materials Engineering, Materials Science +12