Ultrasound in Obstetrics and Gynecology · 2002 · 128 citations · 20 references
MedicineDevelopmental BiologyObstetricsDevelopmental PhysiologyMaternal-fetal MedicineObstetric UltrasoundFetal Anatomy AssessmentFetal AssessmentFetal GrowthFetal Growth AssessmentIntrauterine Growth RestrictionMaternal-fetal PhysiologyFetal Blood FlowFetal Weight EstimationFlow Velocity EstimationFlow Velocity MeasurementsFlow-volume RelationshipsUmbilical Artery Doppler UltrasoundUmbilical Artery Doppler VelocimetryVenous Flow Dynamics
OBJECTIVE: To determine the reproducibility of measurement of umbilical venous volume flow components and to calculate umbilical venous volume flow in normal and growth-restricted (small-for-gestational age) fetuses in a cross-sectional study. METHOD: Using Labview and Imaq-vision software, the cross-sectional inner area of the umbilical vein was traced. Vessel area (mm2) and Doppler-derived time-averaged flow velocity (mm/s) were multiplied to calculate volume flow (mL/min) including flow per kg fetal weight. The coefficient of variation for vessel area and flow velocity scans and tracings were determined (n = 13; 26-35 weeks). Normal charts for components and volume flow were constructed (n = 100; 20-36 weeks) and related to data from growth restricted fetuses (birth weight < 5th centile) (n = 33; 22-36 weeks). In growth-restricted fetuses the umbilical artery pulsatility index was also obtained. RESULTS: Reproducibility: The coefficient of variation was 5.4% (vessel area) and 7.3% (time-averaged velocity) for scans and 6.6% and 10.5% for measurements, resulting in a coefficient of variation of 8.1% (scans) and 11.9% (measurements) for volume flow. A gestational age-related increase exists for vessel area, time-averaged flow velocity and umbilical venous volume flow from 33.2 (SD, 15.2) mL/min at 20 weeks to 221.0 (SD, 32.8) mL/min at 36 weeks of gestation, but there is a reduction from 117.5 (SD, 33.6) mL/min to 78.3 (SD, 12.4) mL/min for volume flow per kg fetal weight. In small-for-gestational age fetuses, the values were below the normal range in 31 of 33 cases for volume flow and in 21 of 33 cases for volume flow per kg fetal weight. Umbilical artery pulsatility index was significantly different between the subsets with normal and those with reduced volume flow per kg fetal weight. CONCLUSIONS: Measurements of umbilical venous vessel area and time-averaged velocity resulted in acceptable reproducibility of volume flow calculations, which show a seven-fold increase at 20-36 weeks of gestation. In growth-restricted fetuses, volume flow is significantly reduced. When calculated per kg/fetus, the values were reduced in 21 (63.6%) out of 33 cases.
20
G.J. Kloosterman · International Journal of Gynecology & Obstetrics · 1970 · 646 citations
Fetal biometry at 14–40 weeks' gestation
R. J. M. Snijders, K. H. Nicolaides · Ultrasound in Obstetrics and Gynecology · 1994 · 499 citations · Full text