Health Physics · 1976 · 80 citations · 0 references
MedicineRadiation OncologyRadiation DosimetryRadiation SafetyRadiobiologyAbsorbed DoseBiological Effects Of RadiationMonte Carlo DosimetryRadiation HealthRadiation Risk AssessmentRadiobiological ModelingBiological DosimetryDose Distribution CalculationsDose StatisticsEnvironmental Radiation DosimetryGamma DosimetryMonte Carlo Dose SimulationRadiation Dose AssessmentRadiation Dose Estimation
The propagation of environmental gamma rays through the human body was calculated using the 3-dimensional Monte-Carlo code DISDOS. These calculations were performed with the aim of determining the gonadal dose with a statistical accuracy of 10% or less for each of the energies considered. The ratio of exposure to absorbed dose in the human body averages about 0.6. A mean annual gonadal dose produced by environmental gamma rays in the U.S. was calculated to be 32 ± 4% mrad/yr. The mean annual dose to the red marrow was calculated to be 29 ± 0.1 % mrad/yr (the errors cited being purely statistical).