Publication | Open Access
Compliance with CPAP therapy in patients with the sleep apnoea/hypopnoea syndrome.
357
Citations
17
References
1994
Year
Patients with sleep apnoea/hypopnoea syndrome used CPAP for less than five hours/night on average with no correlation between severity of sleep apnoea/hypopnoea syndrome and CPAP usage. Patients who complained of side effects used their CPAP therapy less. It is recommended that, as a minimum, CPAP run time should be regularly recorded in all patients receiving CPAP therapy.