Optics Express · 2007 · 26 citations · 17 references
EngineeringBioengineeringBiomedical EngineeringBiomedical ImagingBiomedical OpticsBiophotonicsImage RegistrationMedical ImagingOptical FlowOptical ImagingPolarization OpticsTissue OpticsBiomedical ApplicationsDepolarizationIn Vivo ImagingMueller Matrix ImagingPolarimetric ImagingPolarization ImagingPolarization In Tissue OpticsPolarization Properties Of Tissue
Most Mueller matrix imaging polarimeters implement sequential acquisition of at least 16 raw images of the same object with different incident and detected light polarizations. When this technique is implemented in vivo, the unavoidable motions of the subject may shift and distort the raw images to an extent such that the final Mueller images cannot be extracted. We describe a registration algorithm which solves this problem for the typical conditions of in vivo imaging, e.g. with spatially inhomogeneous medium to strong depolarization. The algorithm, based on the so called "optical flow," is validated experimentally by comparing the Mueller images of a pig skin sample taken in static and in dynamic conditions.
17
Stavros G. Demos, R. R. Alfano · Applied Optics · 1997 · 404 citations
Polarized Light Examination and Photography of the Skin
R. Rox Anderson · Archives of Dermatology · 1991 · 289 citations