Indoor Air · 2006 · 92 citations · 17 references
Natural SciencesArchitectural EngineeringMaterials ScienceAir PollutionAnalytical ChemistryEnvironmental ChemistryAdsorption ProcessesAir PollutantsAir Pollution ChemistryHumidity EffectsRelative HumidityVolatile Organic CompoundsAdsorption CapacityAdsorption Of Volatile Organic CompoundsAdsorption PhenomenaIndoor Air QualityIndoor Volatile Organic CompoundsRelative Humidity EffectsVolatile Compound AdsorptionVolatile Organic Compound Removal
UNLABELLED: This paper presents the results of a factorial experiment design analysis to investigate volatile organic compounds (VOC) adsorption on a ceiling tile. The impacts of three factors, VOC gas phase concentration, relative humidity, and VOC type, as single parameters and as a combination, on adsorption have been investigated. Cyclohexane, toluene, ethyl acetate, isopropyl alcohol and methanol were the five VOCs used in this study. A factor significant level was determined through evaluating its F value and comparing it with the critical value of F distribution at 95% confidence level. It was found that: (i) neither the relative humidity and gas phase concentration nor any interaction effect between them had significant impacts on toluene adsorption on the ceiling tile; (ii) the adsorption isotherm appeared to be linear for the non-polar compounds and non-linear for the semi-polar and polar compounds; (iii) no significant impact of relative humidity on adsorption was observed for most VOC compounds except for methanol; and (iv) the ceiling tile had the highest adsorption capacity toward the polar compounds, followed by the aromatic compounds and aliphatic compounds. In addition, the statistical analysis regarding the experimental results of toluene as a single compound or as a part of a mixture showed that toluene adsorption capacity on the ceiling tile as a single compound was higher than as a part of a mixture. PRACTICAL IMPLICATIONS: Building materials and furnishings may act as source and sink of VOCs in the indoor environment. In this study, a factorial experiment design analysis technique was used to show the impact of three factors, VOC gas phase concentration, relative humidity, and VOC type, as single parameters and as a combination, on the adsorption process (sink effect). The aim was to better understand the interaction between these parameters and to verify the common assumptions made in the model development and measurement of indoor air quality.
17
Design and Analysis: A Researcher's Handbook
Albert E. Beaton, Geoffrey Keppel · American Educational Research Journal · 1975 · 5.9K citations
Arts, Design, Design Theory +3
Design and Analysis: A Researcher's Handbook
John P. Morgan · Technometrics · 2005 · 2.4K citations
Arts, Design, Design Theory +3