The Journal of Urology · 2007 · 38 citations · 11 references
MedicineRadiologyUrologyDiagnostic ImagingDiagnostic RadiologyGenitourinary RadiologyBladder ImagingComputed TomographyGenitourinary ImagingUreteral ImagingUrolithiasis ImagingBladder Stones ImagingContrast-enhanced UrographyCt UrographyMulti-detector Computed TomographyMultidetector Computed TomographyRenal Stone DetectionRenal Stone ImagingUreteral Stone Imaging
PURPOSE: We determined the value of automated coronal reformation using 64-detector computerized tomography for the detection of urinary stones. MATERIALS AND METHODS: A total of 72 patients underwent unenhanced 64-detector computerized tomography to diagnose urinary stones. Two radiologists independently reviewed coronal reformations and axial images at separate reading sessions. The stone detection rate, reader confidence and interpretation time per radiologist were recorded. Two radiologists reviewed coronal and axial images in consensus and served as the reference standard. RESULTS: A total of 175 stones were diagnosed by consensus. Using coronal reformations 162 stones (92.6%) were detected by reader 1 and 157 (89.7%) were detected by reader 2. Using axial images 157 stones (90.3%) were detected by reader 1 and 155 (88.6%) were detected by reader 2. The reading time of coronal reformations was significantly shorter than that of axial images for each reader (p <0.01). Using coronal imaging to complement axial imaging 12 additional stones were detected and 23 were diagnosed with increased confidence by reader 1, while an additional 15 were detected and 8 were diagnosed with increased confidence by reader 2. The mean size of stones detected with coronal reformations alone was significantly smaller than that of the total stones. Excellent interobserver agreement was noted for coronal reformations and axial images (kappa coefficient: 0.91 and 0.904, respectively). CONCLUSIONS: Review of automated coronal reformations allows equally accurate and more rapid detection of urinary stones compared with axial images alone. In addition, coronal reformation of 64-detector computerized tomography adds value when used in conjunction with axial data sets.
11
Acute flank pain: comparison of non-contrast-enhanced CT and intravenous urography.
Robert C. Smith, Arthur T. Rosenfield, K A Choe et al. · Radiology · 1995 · 675 citations
Urinary Tract Abnormalities: Initial Experience with Multi–Detector Row CT Urography
Elaine M. Caoili, Richard H. Cohan, Melvyn Korobkin et al. · Radiology · 2002 · 287 citations
Low-Dose Unenhanced Multidetector CT of Patients with Suspected Renal Colic
Denis Tack, S Sourtzis, Isabelle Delpierre et al. · American Journal of Roentgenology · 2003 · 224 citations
Medicine, Nephrology, Radiology +15