Radiology · 2004 · 284 citations · 20 references
MedicineCardiologyRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyCardiac ImagingCardiovascular ImagingMagnetic Resonance ImagingMyocardial Blood Flow QuantificationMyocardial Perfusion ImagingPerfusion ImagingAbsolute Myocardial Blood FlowAbsolute Myocardial Flow MeasurementBlood FlowMagnetic ResonanceMagnetic Resonance Imaging PerfusionPerfusion Magnetic Resonance ImagingQuantitative Myocardial Perfusion ImagingQuantitative Perfusion Imaging
PURPOSE: To compare fluorescent microsphere measurements of myocardial blood flow (MBF) with qualitative, semiquantitative, and fully quantitative measurements of first-pass perfusion at magnetic resonance (MR) imaging. MATERIALS AND METHODS: Coronary artery occlusion or intracoronary adenosine infusion was successfully performed in 16 beagles; both procedures were performed simultaneously in one animal. MBF was assessed at microsphere analysis. First-pass myocardial perfusion MR imaging was performed during a dual-bolus administration of gadopentetate dimeglumine (0.0025 mmol/kg followed by 0.10 mmol/kg). The absolute myocardial perfusion at MR imaging was calculated by using Fermi function deconvolution methods. Qualitative, semiquantitative, and absolute myocardial perfusion MR imaging measurements were compared with microsphere MBF measurements by using paired t tests, linear correlation, and Bland-Altman analysis. RESULTS: Fully quantitative (ie, absolute) analysis of MBF at MR imaging correlated with microsphere MBF measurement (r = 0.95, P <.001) across the full range of blood flow rates encountered (from 0 to >5.0 mL/min/g). Similar close correlations were observed in endocardial and epicardial segments (representing approximately 0.85 g of the myocardium). With modest increases in MBF, qualitative measurements plateaued in the hyperemic zones. Semiquantitative measurements did not correlate with MBF as well (r = 0.69-0.89); they plateaued around 3.0 mL/min/g. CONCLUSION: Dual-bolus MR imaging enabled accurate measurement of absolute epicardial and endocardial perfusion across a wide range of blood flow rates (0 to >5.0 mL/min/g). Use of qualitative MR imaging measures such as the contrast enhancement ratio led to substantially underestimated hyperemic blood flow measurements.
20
Assessment of Myocardial Perfusion in Coronary Artery Disease by Magnetic Resonance
Juerg Schwitter, Daniel Nanz, Stefan Kneifel et al. · Circulation · 2001 · 662 citations · Full text