Japanese Journal of Applied Physics · 1991 · 21 citations · 7 references
Natural SciencesElectrical EngineeringPhysicsElectric MachinesElectromagneticsElectromagnetismElectric CircuitsElectrical CharacterizationMachine TestingMagnetic CharacterizationMagnetic Circuit AnalysisSurface MagnetismCapacitance MeasurementCapacitance Measurement TechniquesMagnetic Equivalent CircuitsMagnetic Flux SurfacesMagnetic Structure Determination
A new capacitive/resistive probe method for mapping the magnetic surfaces from resistance or capacitance between a magnetic surface and a vacuum vessel was developed and tested. Those resistances and capacitances can be regarded as components of a simple electrical bridge circuit. This method exploits electrical transient response of the bridge circuit for a square pulse. From equiresistance or equicapacitance points, the magnetic surface structure can be deduced. Measurements on the Tohoku University Heliac, which is a small-size standard heliac, show good agreement with numerical calculations. This method is particularly useful for pulse-operated machines.
7
A flexible heliac configuration
J. H. Harris, J. L. Cantrell, T. C. Hender et al. · Nuclear Fusion · 1985 · 54 citations
Design of a helical-axis stellarator
S. Yoshikawa · Nuclear Fusion · 1983 · 31 citations
First studies of plasma confined in a toroidal heliac
B. D. Blackwell, S. M. Hamberger, L. E. Sharp et al. · Nuclear Fusion · 1985 · 24 citations