IEEE Transactions on Magnetics · 1995 · 83 citations · 7 references
EngineeringElectrical EngineeringPhysicsElectric MachinesElectromagneticsElectromagnetismDefect DetectionElectrical MeasurementElectromagnetic CompatibilityMagnetic CharacterizationMagnetic Circuit AnalysisMagnetic FieldsDefect InteractionsEddy Current AnalysisEddy Current InspectionEddy Current ProbesEddy Current SensingEddy CurrentsField MeasurementsMagnetic Field Measurements
The Remote Field Eddy Current (RFEC) technique uses an internal probe to inspect conducting tubes nondestructively. A coaxial solenoidal exciter, energized with low frequency AC, and detector coils near the inside of the pipe wall are separated by about two pipe diameters to obtain through wall transmission and equal sensitivity to defects on the outside or inside of the pipe wall. Calculation methods are outlined and the voltage plane polar plot signal representation for defect measurement is described. Slit defect interactions in ferromagnetic and non-ferromagnetic tubes are discussed. Defect-induced anomalous fields are interpreted in terms of anomalous source eddy current and missing magnetization defect models. The use of computer animations to represent the time variations of high resolution field measurements and calculations is described.
7
Analytical Solutions to Eddy-Current Probe-Coil Problems
C.V. Dodd, W. E. Deeds · Journal of Applied Physics · 1968 · 1.2K citations
The remote field eddy current inspection technique
T.R. Schmidt · Materials Evaluation · 1984 · 102 citations
A finite element study of the remote field eddy current phenomenon
W. Lord, Y.S. Sun, Satish Udpa et al. · IEEE Transactions on Magnetics · 1988 · 85 citations