Journal of Chromatography B Biomedical Sciences and Applications · 1998 · 44 citations · 11 references
PharmacyPharmaceutical AnalysisPharmacologyAnalytical ChemistryChromatographic AnalysisMass Spectrometric AnalysisAnalytical ChromatographyBioanalytical Method ValidationChromatographyInstrumental AnalysisLiquid ChromatographyMass SpectrometryBioanalytical ApplicationsBioanalytical ChromatographyCollision-induced DissociationIon Trap Mass SpectrometryLiquid Chromatography-mass SpectrometryLiquid Chromatography-mass Spectrometry AnalysisTandem Mass SpectrometryTandem Mass Spectrometry Analysis
This report evaluates the use of a quadrupolar ion trap for quantitation in a bioanalytical laboratory. The evaluation was accomplished with the cross-validation of an LC-MS-MS quantitative method previously validated on a triple quadrupole mass spectrometer. The method was a multi-level determination of the anti-obesity drug, orlistat, in human plasma. The method has been refined previously on a triple quadrupole instrument to provide rapid sample throughput with robust reproducibility at sub-nanogram detection limits. Optimization of the method on the ion trap required improved chromatographic separation of orlistat from interfering plasma matrix components coextracted during the initial liquid-liquid extraction of plasma samples. The ion trap produces full-scan collision-induced dissociation mass spectra containing characteristic orlistat fragment ions that are useful for quantitation. Data collection on the ion trap required a precursor ion isolation width of 3.0 Da and optimal quantitative results were obtained when three fragment ions were monitored with a 1.8 Da window for each ion. Although a direct cross-validation between the ion trap and the tandem triple quadrupole mass spectrometer was not possible, quantitative results for orlistat comparable to those obtained from the triple quadrupole instrument were achieved by the ion trap with the modified method. The limit of quantitation for orlistat in plasma on the ion trap was 0.3 ng ml(-1) with a linear dynamic range of 0.3 to 10 ng ml(-1). Precision and accuracy varied from 4 to 15% over the quantitation range. The overall results provide an example of the utility of an ion trap in bioanalytical work.
11
R. Graham Cooks, Gary L. Glish, Scott A. McLuckey et al. · Chemical & Engineering News · 1991 · 287 citations
Lipase inhibition: a novel concept in the treatment of obesity.
Marjolein Drent, E. A. van der Veen · PubMed · 1993 · 151 citations
Ion trap mass spectrometer—past, present, and future (?)
John F. J. Todd · Mass Spectrometry Reviews · 1991 · 146 citations