An intravasal non-occlusive contraceptive device in rats

M. M. Misro, Harpreet Kaur, Sudha Mahajan, S. K. Guha

Reproduction · 1982 · 10 citations · 5 references

DOIFull text

Open access

Concepts

Abstract

An implantable miniature biogalvanic cell was developed to kill the spermatozoa in the vas deferens by an electric current. Experiments in vitro and in vivo showed that a combination of aluminum/silver electrodes connected with platinum wires with the vas deferens fluid as n electrolyte is effective in killing spermatozoa. Female rats paired with males having biogalvanic devices in the vas deferens, which remained patent, did not produce any young.

References

5