Publication | Closed Access
Use of Premixed Insulin Among the Elderly: Reduction of errors in patient preparation of mixtures
51
Citations
0
References
1992
Year
While the quality of the metabolic control was the same whether patients used self-mixed or premixed insulin, the in vitro skills test indicated that insulin preparation by elderly patients is highly inaccurate. In some patients, a modification of the contents of the insulin is likely to occur in a few days. The use of premixed insulins should lessen the errors that occur in mixing insulins and from the contamination of the second insulin vial. Draw-up errors could partially account for the lack of improvement of glucose control during the period when patients received premixed insulins. A longer observation period probably is needed to assess appreciable changes in the quality of diabetes control.